Assured, repeatable accuracy to enable safe, effective weaning.
What is Microflow used for?
Microflow is primarily used to supply supplementary oxygen to infants with bronchopulmonary dysplasia (BPD).
BPD is common in very low birth weight and pre-term infants that have needed mechanical ventilation or have been treated with high oxygen concentrations due to respiratory distress syndrome (RDS)/ chronic lung disease (CLD).
The risk of RDS/CLD is inversely related to birth weight and gestational age.
Infants may need very low supplementary oxygen for many months to compensatefor underdeveloped lungs.
Microflow benefits
- Enables baby to receive oxygen therapy at home, putting families together sooner and increasing parent satisfaction
- Less time in hospital, lower cost of care
- Accurate, repeatable steps
- Micro step changes in flow
- Enables low flow rates to achieve target saturation
- Enables oxygen flow to be weaned
DISS Inlet • Barbed Outlet
| Item# | Flow Range |
| RES8160048 | A 0.02-3 LPM |
| RES8160050 | E 0.01-1 LPM |
DISS Inlet • DISS Outlet
| Item# | Flow Range |
| RES8160049 | A 0.02-3 LPM |
| RES8160051 | E 0.01-1 LPM |
LPM
| Dial Position | Off | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
| Range A | 0 | 0.02 | 0.03 | 0.05 | 0.08 | 0.12 | 0.2 | 0.3 | 0.5 | 0.75 | 1 | 3 |
| Range E | 0 | 0.01 | 0.02 | 0.03 | 0.04 | 0.05 | 0.06 | 0.07 | 0.08 | 0.09 | 0.1 | 1 |
“We are using Microdial for infants on a small amount of oxygen, for more precise oxygen delivery and titration. Other flowmeters tend to fluctuate more easily and are not as precise as the Microdial.”
— M.W., NICU Clinical Educator/Outreach Coordinator
Find your rep

Territory Sales Manager – Southwest
moc.s1780509240chtes1780509240nus@e1780509240tiakc1780509240intne1780509240vse1780509240
Egle Sventnickaite
+1-872-258-1654moc.s1780509240chtes1780509240nus@e1780509240tiakc1780509240intne1780509240vse1780509240

Sales Representative
moc.s1780509240chtes1780509240nus@s1780509240somm1780509240
Mason Moss
+1-262-788-1862moc.s1780509240chtes1780509240nus@s1780509240somm1780509240

Territory Sales Manager – East
moc.s1780509240chtes1780509240nus@r1780509240newo1780509240
Owen Ruth
+1-312-533-2451moc.s1780509240chtes1780509240nus@r1780509240newo1780509240

Sales Representative
moc.s1780509240chtes1780509240nus@s1780509240ehgie1780509240gc1780509240
Cindy Geighes
+1-312-533-2478moc.s1780509240chtes1780509240nus@s1780509240ehgie1780509240gc1780509240

Sales Representative
moc.s1780509240chtes1780509240nus@o1780509240nidua1780509240bh1780509240
Hunter Baudino
+1-262-788-1855moc.s1780509240chtes1780509240nus@o1780509240nidua1780509240bh1780509240

Sales Representative
moc.s1780509240chtes1780509240nus@o1780509240tomen1780509240akw1780509240
Wyatt Kanemoto
+1-262-788-8941moc.s1780509240chtes1780509240nus@o1780509240tomen1780509240akw1780509240
Director, Strategic Accounts
moc.s1780509240chtes1780509240nus@a1780509240sil1780509240
Lisa Iannazzone RN, BSN
+1-636-222-3134moc.s1780509240chtes1780509240nus@a1780509240sil1780509240
Manager, Strategic Accounts
moc.s1780509240chtes1780509240nus@g1780509240innis1780509240m1780509240
Maggie Sinnig
+1-562-556-7137moc.s1780509240chtes1780509240nus@g1780509240innis1780509240m1780509240
Manager, Product & Business Development
moc.s1780509240chtes1780509240nus@r1780509240anumt1780509240
Tom Munar
+1-312-533-2476moc.s1780509240chtes1780509240nus@r1780509240anumt1780509240
RRT Clinical Specialist